Please enter your search keywords!

2310 Unidirectional Explosion Isolation Flap Valve

Materials: Housing Carbon Steel + Valve Disc Stainless Steel

Pressure Drop:≤500Pa@25M/S

On-site servicing without pipeline removal

Standard horizontal mounting,Vertical installation possible for specific applications

Normally open valve disc design,Optional blast detection sensor for closure monitoring

Integrated anti-bounce locking mechanism

Magnetic actuation for ultra-fast response

Aerodynamic internal profile prevents dust accumulation

Demand consultation
2310 Unidirectional Explosion Isolation Flap Valve

Product Overview

In reality, many containers are connected with each other, such as dust collector and pipe、food bin and pipe, once adevice explodes, the flame and air pressure will spread to other devices along with the pipe ,thus causing secondary explosion or multiple explosions of the device. Equipped the explosion isolation flap valve can effectively prevent the spread of explosion, protect adjacent device or workshop which can prevent secondary explosion or multiple explosions.


Certifications
BasCo offers a full range ofDust Explosion Protection. It has obtained qualification certificates including ATEX, EAC, SIL and Type Test Certificates, and is equipped with a complete testing system. We can provide users with safe, reliable and customized solutions and products.


Working principle

During a dust explosion, the shockwave precedes the flame front. The explosion isolation valve rapidly closes upon detecting the shockwave and is securely locked in place by its self-locking mechanism, effectively preventing the propagation of both flames and pressure waves. 

After the explosion event, the valve can be manually reset. Following simple maintenance and safety evaluation, it becomes ready for reuse. During normal operation, the valve disc remains open through an assisted opening device.


Attachment

Blast Sensor: HE


Use and Maintenance

It is important to ensure that the bursting valve is open before the system fan is operated to prevent damage to the fan and other equipment due to locking of the valve flap closure. Before operating the system fan, it is necessary to ensure that the explosion-proof valve is in the open state to prevent damage to the fan and other equipment due to the valve disc being closed and locked.

After installation and use, maintenance should be carried out at least once a month, and the frequency of maintenance can be appropriately increased according to specific working conditions. 

After maintenance and assembly, a sealing test should be conducted and detailed records should be made for future reference.


Attachment


Outline drawing Name Model Applicable range
Explosion-proof junction box BF-FJF-01

Ex db IIB T4 Gb

Ex tb IIIC T80℃ Db

Protection rating:IP66

Specifications


Specification L×W×H(mm) Explosion Grade
DN100 409×324×497 ST1,ST2
DN150 587×386×550 ST1,ST2
DN200 587×386×550 ST1,ST2
DN250 628×443×624 ST1,ST2
DN300 778×507×693 ST1,ST2
DN350 868×641×788 ST1,ST2
DN400 946×641×813 ST1,ST2
DN450 1093×795×922 ST1,ST2
DN500 1093×795×922 ST1,ST2
DN550 1240×885×1020 ST1,ST2
DN600 1240×885×1074 ST1,ST2
DN650 1390×989×1191 ST1
DN700 1390×989×1191 ST1
DN750 1525×1089×1304 ST1
DN800 1525×1089×1304 ST1
DN850 1668×1189×1441 ST1
DN900 1668×1189×1416 ST1
DN950 1957×1310×1540 ST1
DN1000 1957×1310×1540 ST1

*Content is for reference only. Contact us for more details.

Downloads

  • 2310 One-way explosion-proof valves
    2310 One-way explosion-proof valves
Consulting
Contact *
Tel
Mail *
Company Name
Requirement Description

I read and agree to Bafang Safety Equipment《Privacy Policy》

Copyright © Jiangsu Bafang Safety Device Co., LTD. All Rights Reserved

Sitemap | Legal Statement | Privacy Policy |