Please enter your search keywords!

2210 Non-reclosing Type Flameless Explosion Venting Device

Material: Carbon steel shell + stainless steel filter screen

The flameless release device does not require special maintenance

The flange interface can be customized

Provide various forms of flameless venting structures to meet different working conditions, such as circular, rectangular, and square.

Demand consultation
2210 Non-reclosing Type Flameless Explosion Venting Device

Product Overview

Flameless explosion venting device can be used for the protection of indoor and outdoor dust explosion, without other operating costs, easy installation, and no need to install pressure relief pipe. It shall at least consist of a explosion venting panel and fire resisting components.


Certifications
BasCo offers a full range ofDust Explosion Protection. It has obtained qualification certificates including ATEX, EAC, SIL and Type Test Certificates, and is equipped with a complete testing system. We can provide users with safe, reliable and customized solutions and products.


Working Principle
When an explosion occurs, the explosion venting panel opens, and then the fire passes through the mesh fire resisting components, the fire resisting components will exchange heat with fire, quickly cooling the high temperature, relieving pressure and fumes to ensure the fire will not spread so that prevent it from secondary explosion or multiple explosions, at the same time, the pressure waves or noise generated by the explosion will be minimized.


Useage and Maintenance

The flameless venting device operates on a passive and mechanical principle, and does not require debugging after installation.

It is recommended to define a safe area according to the diagram below to ensure that no additional harm is caused in the event of a dust explosion. Among them: D1>1m (for equipment buildings); D2>2.5m (for personnel)

Regularly inspect the surface of the flameless discharge device for dust, snow, ice, or other debris that may affect the normal function of the pressure relief device. If any, take appropriate measures to remove them.

Regularly inspect the damage of the pressure relief component (bursting disc), and the inspection cycle should not exceed one month.

Regularly check whether the fire extinguishing components are blocked, and the inspection cycle should not exceed one week.

If the pressure relief component is found to be damaged, it should be stopped and replaced in a timely manner. During the replacement process, it should be ensured that there is no residual dust or effective ignition source.

If there is an optional alarm output, please regularly check if there are any abnormalities in the circuit, and the inspection cycle is recommended not to exceed one week.

If powder or gas leakage is found in the flameless discharge device, it may be due to overpressure explosion of the blasting plate, which can be preliminarily inspected through the inspection port.

If there is an optional alarm output, when there is a signal displayed on the alarm output, it indicates that the blasting board has ruptured and needs to be replaced.

When there is a dust explosion, the flameless release device releases smoke accompanied by sound. If this situation occurs, please stop the machine immediately for inspection.

After a dust explosion, do not touch the flameless discharge device to avoid burns.


Attachment

Outline drawing Name Model Applicable range
Explosion-proof travel switch BF-FJF-06

Ex db IIB T6 Gb

Ex tb IIIC T80℃ Db

Ex db IIC T6 Gb

Ex tb IIIC T80℃ Db

Rated voltage:DC 12/24/36/110/220V

AC 24/36/110/220/380V

Protection rating:IP66

Travel switch BF-FJF-07

AC15 240VAC 3A

DC13 220VDC 0.3A

Protection rating:IP65

Explosion-proof proximity switch BF-FJF-04

Ex mb IIC T6 Gb

Ex tb IIIC T80℃ Db

Rated voltage:DC 10-36V

Protection rating:IP66

Proximity switch BF-FJF-05

Rated voltage:DC 6-36V

Protection rating:IP54-IP67

Specifications


Parameters


Specifications Dimensions
(mm)
Vent Area
(cm2)
EPS/ELS EP/EL
230×305 494×342×405 701 591
240×410 535×362×519 984 916
305×457 571×421×610 1393 1238
410×410 807×516×516 1681 1579
457×457 799×569×612 2088 1887
457×610 799×573×765 2787 2563
457×762 799×573×917 3482 3235
457×915 799×573×1070 4181 3911
610×610 1029×726×765 3721 3451
610×762 1029×726×917 4648 4355
610×915 1029×726×1070 5581 5265
610×1118 1029×726×1273 6819 6473
762×915 1257×878×1070 6972 6610
762×1016 1257×878×1070 7741 7327
762×1118 1257×878×1273 8519 8127
915×915 1486×1031×1070 8372 7965
1118×1118 1791×1234×1273 12499 12000

*Content is for reference only. Contact us for more details.


Parameters


Model ΦD±5 H±5 EL Vent Area(mm³) EPS/ELS Vent Area(mm³)
FEV-Y-200 385 585 24600 27300
FEV-Y-300 485 685 57400 61400
FEV-Y-400 605 885 114800 120500
FEV-Y-500 705 1087 177700 184700
FEV-Y-600 805 1187 254200 262600
FEV-Y-700 905 1387 344400 354200
FEV-Y-800 1005 1587 448300 459400

*Content is for reference only. Contact us for more details.

Downloads

  • 2210 Flameless Venting Device
    2210 Flameless Venting Device
Consulting
Contact *
Tel
Mail *
Company Name
Requirement Description

I read and agree to Bafang Safety Equipment《Privacy Policy》

Copyright © Jiangsu Bafang Safety Device Co., LTD. All Rights Reserved

Sitemap | Legal Statement | Privacy Policy |