Please enter your search keywords!

5200 In-Line Pressure Vacuum Relief Valve

Dual guide rail system , smooth stroke and less wear

Leakage is much less than API2000 standard and maintains high setting accuracy(±3%)

Full start at 10% overpressure

Valve core and valve seat assembly can be replaced on site

Supports ANSI, DIN, and HG/T20592~20635~2009 flanges

Demand consultation
5200 In-Line Pressure Vacuum Relief Valve

Product Overview

The 5200 In Line Breather Valve maintains a sealed state. When the system pressure or vacuum exceeds the valve setting value, the valve core is lifted, the sealing state between the valve seat and the valve core is broken, and the pressure or vacuum accumulation is released. Once the release is completed, the valve remains sealed again.

Installation location: Connect the storage tank and the recycling pipeline separately by flanges.


Certifications
BasCo pressure vacuum relief valve are designed in accordance with international and domestic standards including SY/T0511 and API 2000-2020, and have obtained qualification certifications such as ATEX, EAC, DNV, TS, CCS and Type Test Certificate.

Specifications

Setting range
Model Size Pressure Vacuum
5210 1.5"(DN40)~12"(DN300) 0.2~6.9KPa(2~69mbar) 0.2~6.9KPa(2~69mbar)
5220 1.5"(DN40)~12"(DN300) 6.9~100KPa(69~1000mbar) 0.2~6.9KPa(2~69mbar)
5230 1.5"(DN40)~12"(DN300) 6.9~100KPa(69~1000mbar) 6.9~100KPa(69~1000mbar)
5240 1.5"(DN40)~12"(DN300) 0.2~6.9KPa(2~69mbar) 6.9~100KPa(69~1000mbar)
Model Rules
Item Series Inlet Size
(DN)
Outlet Size
(DN)
Body Material Disc/Seat Material Diaphragm Material Pressure/Vacuum Option
e.g. 5210 - 50 x 50 - 6 6 1 - 1.8KPa/-0.3KPa
- J
Content 5210
5220
5230
5240

40
50
80
100
150
200
250
300

40
50
80
100
150
200
250
300

4 304
6 316L
D 2205
C C.S
H HC
Q Other
4 304
6 316L
D 2205
A Al
H HC
Q Other
1 FEP
2 PFA
3 FKM
4 FFKM
Y Hard Seal
Q Other

KPa KPa
mbar mbar
InH₂O InH₂O

J Heat tracing jacket
T Teflon Coating
Q Other
Key Parameter List
Model  Inlet Connection
In(mm)
Outlet Connection
mm
A
total length
mm
E
Center Height
mm
H1
Total height
mm
H2
Total height
mm
D
Center Width
mm
5200 2(50) 50 307 195 277 Variable value 110
3(80) 80 357 217 321 127
4(100) 100 417 256 380 146
6(150) 150 524 346 506 176
8(200) 200 649 397 605 207
10 (250) 250 747 452 699 232
12(300) 300 948 523 812 288
*Unit weight, indicating the net weight (in kilograms) of the valve at the standard set pressure (2mba pressure -2mbar  vacuum), excluding the weight of the transport box. The total shipping weight needs to be increased by 20% (domestic only). Parameter content is for reference only, more requirements please contact us.

Downloads

  • 5200 In-Line Pressure Vacuum Relief Valve
    5200 In-Line Pressure Vacuum Relief Valve
Consulting
Contact *
Tel
Mail *
Company Name
Requirement Description

I read and agree to Bafang Safety Equipment《Privacy Policy》

Copyright © Jiangsu Bafang Safety Device Co., LTD. All Rights Reserved

Sitemap | Legal Statement | Privacy Policy |