The convex of reverse acting rupture disc is on the high pressure process side. When the metal disc is compression-loaded, the disk reverses with a crocodile tooth diaphragm cutting it to relieve pressure.
Options
Fluoroplastic lining or coating.
BI burst indicator sensor
*Note: Temperature resistance of lining and BI is lower than the strength membrane
Suitable for safety valve isolation/
When installed beneath a safety valve, the rupture disc isolates the valve's working components from corrosive media.
Tolerance / (GB567-2012)
| bursting pressure bar |
≥0.01~<0.1 | ≥0.1~<1 | ≥1~<3 | ≥3~<1000 | ≥1000~<5000 |
| Tolerance | ±50% | ±25% | ±0.015MPa | ±5% | ±4% |