flameless venting device (diving)

Material: Carbon Steel Housing + Stainless Steel Filter

Flameless relief device requires no special maintenance

Flange connection can be customized

A variety of flameless structures are available to meet the needs of different working conditions, such as: round, rectangular, square.

Demand consultation
flameless venting device (diving)

Product Overview

Can be used for protection against indoor or outdoor dust explosions, with no other running costs, easy installation and no need to install pressure relief conduits. It consists at least of a rupture plate and a flame arresting element.


Principle of operation

When an explosion occurs, the rupture plate opens, and when the flame passes through the mesh flame arresting element, the flame arresting element exchanges heat with the flame, rapidly cools down the high temperature flame, releases pressure and smoke, ensures that the flame is not propagated to avoid causing a secondary explosion or multiple explosions, and at the same time, the pressure wave or noise generated by the explosion will be reduced to a lower level.


Use and Maintenance

The flameless relief device is a passive, mechanical principle of action and requires no commissioning after installation.
It is recommended that the safety zone be defined according to the diagram below to ensure that no additional injuries are caused in the event of a dust explosion. Where: d1 > 1m (for equipment buildings); d2 > 2.5m (for personnel).
Regularly inspect the surface of the flameless relief device for accumulation of dust, snow, ice, or the presence of other buildup that interferes with the proper functioning of the relief device, and if so, remove it by appropriate means.
Regularly inspect the pressure relief element (bursting plate) for breakage, the inspection period should be no more than 1 month.
Regularly check the fire extinguishing element for blockage, the inspection period should be no more than 1 week.
If the pressure relief element is found to be broken, it should be shut down and replaced in time. During the replacement process, it should be ensured that there is no residual dust or effective ignition source.
If there is an optional alarm output, please check the wiring regularly for any abnormality, and the inspection cycle is recommended to be no more than 1 week.
If the flameless relief device is found to be leaking powder or air, the rupture plate may have burst due to overpressure, which can be initially checked through the inspection port.
If there is an optional alarm output, when there is a signal display on the alarm output, it means that the bursting board is ruptured and the replacement of the bursting board is required.
When the dust explosion, the flameless relief device releases smoke and accompanied by sound, if this happens, please stop the machine immediately to check.
After the dust explosion, please do not touch the flameless relief device to avoid burns.

Specifications

Specification Dimensions
(mm)
Discharge area(cm2)
EPS/ELS EP/EL
230×305 494×342×405 701 591
305×457 571×421×610 1393 1238
457×457 799×569×612 2088 1887
457×610 799×573×765 2787 2563
457×762 799×573×917 3482 3235
457×915 799×573×1070 4181 3911
610×610 1029×726×765 3721 3451
610×762 1029×726×917 4648 4355
610×915 1029×726×1070 5581 5265
610×1118 1029×726×1273 6819 6473
762×915 1257×878×1070 6972 6610
762×1016 1257×878×1070 7741 7327
762×1118 1257×878×1273 8519 8127
915×915 1486×1031×1070 8372 7965
1118×1118 1791×1234×1273 12499 12000
* The content is for reference only. Please contact us for more information.